Seon Maintenance and Troubleshooting Guide R004 45
Output
If the user-selected G Sensor value is Exceeded,
the DVR will trigger the following output
[Off], Log, E-mail, S01, S02, S03, S04,
S05, S06, S07, S08, S09, S10, ALM1,
ALM2, ALM3, ALM4
.
Peak
Display only - Indicates peak detected levels for the axis
To calibrate
the Inertia/G
Sensor:
1. Make sure the DVR is mounted securely in a horizontal or vertical position.
2. Start the calibration process by pressing Field Calibrate. When the process is
complete, a Calibration Complete message is displayed.
3. End the process by pressing the Stop button.